System Requirements
•Throughput: Up to 225 tests/Hour (not including ISE tests).
•Test Method: End point, Fixed time, Kinetic.
•Test Sequence: Discrete, Random access, STAT can be insertes at any time. Test sequence can be sorted by samples or items.
•Spectometer: Enclosed array of spectometer and photodiodes, maintenance free.
•Cuvette Washing: Auto wash the cuvettes through 8 segments washing pipe and continuous use them (optional).
•Reaction Detect: Monitor 81 cuvettes' reaction at the same time.
•Photometric Process: The internal timebetween two consecutive photometric points are exactly the same.
•Pipeline System: Pressure auto released pumps and double filters to protect pumps and valves.
•Gearing: Plastic gear leads lower noise and accuracy of positioning of moving pants.
•Environmental resistance: resistant from dust and water vapor.

Optical System
•Light Source: 12V 20W, halogen lamp with lifetime more than 2000 hours.
•Spectometer: Post spectometer with arrayed and sealed filters, maintenance free.
•Wavelength: 340nm, 405nm, 510nm, 546nm, 578nm,630nm, 670nm.
•Absorbance Range: 0-6.

Reaction Range
•Cuvette: Permanent UV free glass cuvette.
•Reaction Disc: Discal reaction disc with 81 disposable cuvettes.
•Reaction Volume 150μL-600μL.
•Heater: Solid and sealed heater leads temperature raise rapidly and steady and maintenance free.
•Temperatures: 37C +0.1C.

Sample/Reagent/Stirrer System
•Sample Volume: 2μL-30μL, step by 0.1 μL.
•Sample Disc: 60 positions for primary tubes and secondary cups.
•Reagent Volume: 20μL-300μL, step by 1μL.
•Reagent Disc: Provide 60 reagent bottle positions.
•Reagent Bottle: Particular reagent bottle without dead volume.
•Reagent Cooling: Continuous cooling system according to the principle of peltier.
•Probe: Inner and outer walls are highly polished leads carry-over < 0.1% level detection and vertical and horizontal collision protection..
•Stirrer: Paddle stirrer coated with Teflon, stir immediately after sampling.
•Water Consume: <1.5L/hour.
•Carry Over: Optimized item test sequence and reinforced washing process, lower the carry over and avoid probe being clotted.

Callibration/QC
•Callibration Type: Single point linear, two points linear, Multipoints linear, Logit-4P, Logit-5P, Spline, Exponential 5P, Polynomial 5P, Auto choose the best fittest callibration curve.
•QC Type: Real time QC, daily QC, day to day QC.
•QC Chart: L-J, Cumulative sum check, Twin Plot.
•QC Rule: Customized QC rule in order to adapt different item's requirements.

Operational system
•Operational System: VISTA, Windows XP, Windows 2000.
•Memory: Auto save and recover the results.
•Report Format: Customized report format.
•Status Check: Real time check the working status of the analyzer.

Power/ Diminsion
•Voltage: AC 85V~264V, 55Hz +8Hz, Auto adaption according to the imput voltage.
•Power: up to 350VA.
•Dimension: 850mm x 650mm x 1067mm (LxWxH)
•Net Weight: 90Kg.

 

 
GS 300
 
   
   
   